OmniPLC FC23 Authenticated Modbus Writer

Status: Alpha Protocol: Modbus Function Code: 23 Tested On: HTB Alchemy ICS/OT Security MIT License

Protocol: Modbus TCP (Function Code 23 - Read/Write Multiple Registers)
Compatibility: Tested with pymodbus==3.0.0rc1


Overview

This Python script performs authenticated writes to Modbus holding registers using function code 23 (FC23). It was built to interact with the OmniPLC 3000 and similar ICS/PLC systems where write operations are password-protected via in-band Modbus memory registers.


Features

  • FC23 read/write combo support
  • Authentication via ASCII password (e.g., "Hacker1337#4")
  • Post-auth write delay to simulate server-side unlock window
  • Supports:
    • Hex values (e.g. 0x64)
    • ASCII strings
    • IEEE 754 float-to-register conversions (--float mode)

MITRE ATT&CK for ICS Mapping

Capability ATT&CK Technique ID
Unauthorized Modbus Writes Manipulation of Control T0834
Targeting Registers/PLC Memory Access to Program Organization Units T0865
Privilege Abuse via Auth Registers Exploitation for Evasion T0828
Stateful Timing to Evade Detection Inhibit Response Function T0814
Reading Sensitive Register Data Monitor Process State T0809

Example Use Case

python3  omni_fc23_writer.py \
  --host 172.19.8.3 \
  --auth "Hacker1337#4" \
  --auth-addr 3890 \
  --address 1027 \
  --data 0x64

Command-Line Arguments

Flag Description
--host Modbus TCP IP address
--port (Optional) Default is 502
--unit-id (Optional) Modbus Unit ID, default is 1
--auth ASCII password for FC23 auth (e.g. "Hacker1337#4")
--auth-addr Register address to authenticate against
--address Register address to write data to
--data Data to write (ASCII or hex like 0x64)
--float (Optional) Convert float to 2x registers
--delay Wait time (in seconds) after auth (default: 0.5)

Dependencies

pip install pymodbus==3.0.0rc1

Disclaimer

This tool is provided strictly for educational and ethical security testing purposes.

Modbus is an unauthenticated protocol designed for trusted environments. Improper use may result in physical system disruption or damage.

By using this software, you agree to the following:

  • You will only use it on systems you own or have explicit written permission to test.
  • You will not use it in production, critical infrastructure, or safety systems.
  • The author assumes no liability for any damage caused by misuse or unauthorized deployment.

This script is intended to promote awareness of insecure-by-design ICS protocols and assist in defensive research, training, and ethical penetration testing.