import re
import json
import requests
import time
import serial
# ############Disable HTTPS warning and allow to send data to splunk with out signed ssl cert ################
from urllib3.exceptions import InsecureRequestWarning
requests.packages.urllib3.disable_warnings(category=InsecureRequestWarning)
##############################################################################################################
serial_port = serial.Serial(
"/dev/ttyS0", # your serial port name,for rasberry pi 2,3 and 4 ttyS0 should be correct, make sure to disable shell via serial before
baudrate=115200,
parity=serial.PARITY_NONE,
stopbits=serial.STOPBITS_ONE,
bytesize=serial.EIGHTBITS,
timeout=None,
rtscts=False,
dsrdtr=False,
xonxoff=False
)
S_URL = 'https://<change me to splunk hec uri:8088/services/collector/raw'
authHeader = {'Authorization': 'Splunk <change to splunk hec token'}
def splunk_hec(dictionary):
message = json.dumps(dictionary)
try:
x = requests.post(S_URL, headers=authHeader, data=message, verify=False, timeout=1)
except: # very greedy, could be refined.
print("Splunk log error")
while True:
result = str(serial_port.read_until(b'\r\n!')) # Reading data until it reaches \r\n! <- change according to the data from your meter.
print(result)
results = re.findall(r'(?<=\()[0-9.]+', result)
dictionary ={
"time": str(int(time.time())),
"meter_active_out": results[1],
"meter_active_in": results[2],
"meter_reactive_out": results[3],
"meter_reactive_in": results[4],
"active_usage_out": results[5],
"active_usage_in": results[6],
"reactive_usage_out": results[7],
"reactive_usage_in": results[8],
"L1_active_usage_out": results[9],
"L1_active_usage_in": results[10],
"L2_active_usage_out": results[11],
"L2_active_usage_in": results[12],
"L3_active_usage_out": results[13],
"L3_active_usage_in": results[14],
"L1_reactive_usage_out": results[15],
"L1_reactive_usage_in": results[16],
"L2_reactive_usage_out": results[17],
"L2_reactive_usage_in": results[18],
"L3_reactive_usage_out": results[19],
"L3_reactive_usage_in": results[20],
"L1_phase_voltage": results[21],
"L2_phase_voltage": results[22],
"L3_phase_voltage": results[23],
"L1_phase_current": results[24],
"L2_phase_current": results[25],
"L3_phase_current": results[26]
}
splunk_hec(dictionary)
serial_port.close()