Notifications
You must be signed in to change notification settings - Fork 18
Migration guide v2.9.0
The TopologyCalculation class used to partition a VoltageLevelGraph into several TopologicallyConnectedNodeSets can be customized since this release with in particular an extremity criteria different from the default one (open switches). Therefore, as a border node for a connected component can now be something else than a SwitchNode, TopologicallyConnectedNodeSets now contains a Set<Node> for the border nodes. The following changes also occured:
-
TopologicallyConnectedNodeSets::getBorderSwitchNodesSetis renamed toTopologicallyConnectedNodeSets::getBorderNodesand returns aSet<Node>instead of aSet<SwitchNode> -
TopologicallyConnectedNodeSets::getNodesSetis renamed toTopologicallyConnectedNodeSets::getNodes -
TopologyCalculation::run(VoltageLevelGraph)static method has been replaced byTopologyCalculation::findConnectedNodeSets(VoltageLevelGraph), the custom extremity criteria is given inTopologyCalculationnew constructor. - A new
TopologyCalculation::run(VoltageLevelGraph, Predicate<TopologicallyConnectedNodesSet>)method has been introduced to filter theList<TopologicallyConnectedNodesSet>results

Since this release, an information component (BusInfo) can be added on each busbar, similarly to the FeederInfo for feeders. This component is either on the left of the busbar or on its right. To use this new feature:
- Use
Optional<BusInfo> getBusInfo(BusNode node)of interfaceDiagramLabelProviderto provide theBusInfofor each busbar. - Use
PositionVoltageLevelLayoutFactory::setBusInfoMaporBlockOrganizernew constructor with theMap<String, Side>map between bus ids and left/right side. To get the map consistent with theDiagramLabelProvideryou're using, you can get that map withDiagramLabelProvider::getBusInfoSides(VoltageLevelGraph)utility method. - Use the interface
DiagramStyleProvider::getBusInfoStyle(BusInfo)to provide the proper CSS classes for eachBusInfo. - Use the new
LayoutParameter::busInfoMarginto set the margin between the busbar extremity and the component.
Since this release, the classes NetworkGraphBuilder and RawGraphBuilder have been moved to a new builders package. Besides the inner classes RawGraphBuilder.VoltageLevelBuilder and RawGraphBuilder.SubstationBuilder have been moved to independent classes VoltageLevelRawBuilder and SubstationRawBuilder in this same builders package.
A new parameters has been introduced in this release: LayoutParameters::busbarsAlignment. It allows to align the busbars in a substation (either on first or last busbar, or on the middle of the busbar sections) when layoutParameters.isAdaptCellHeightToContent() is true. Set this parameter to Alignment.NONE if you want the previous behaviour (no bus bar alignment, but voltage levels top alignment).