Notifications
You must be signed in to change notification settings - Fork 41
Open
Description
Describe the bug
This is apparently different behavior for ionized sulfonamides depending on whether MOZYME is used or not. This is any groups with smiles string S(=O)(=O)[NH-].
With MOZYME, if the correct -1 charge is given as an input, there is an error; without MOZYME it works.
To Reproduce
Input:
MOZYME XYZ PM6-D3H4X EPS=78.5 1SCF CHARGE=-1 THREADS=64
C -5.005000 1 3.851000 1 15.504000 1
N -5.426000 1 1.038000 1 15.914000 1
O -4.902000 1 2.759000 1 17.839001 1
C -3.857000 1 3.699000 1 14.733000 1
H -3.319528 1 2.750854 1 14.748594 1
O -7.069000 1 2.673000 1 16.502001 1
C -3.383000 1 4.751000 1 13.936000 1
H -2.488679 1 4.609419 1 13.329168 1
C -4.049000 1 5.980000 1 13.914000 1
H -3.661553 1 6.813045 1 13.327466 1
C -5.231000 1 6.118000 1 14.666000 1
H -5.786553 1 7.055192 1 14.632366 1
C -5.698000 1 5.064000 1 15.455000 1
H -6.610806 1 5.188556 1 16.037554 1
S -5.599000 1 2.556000 1 16.565001 1
H -4.490000 1 0.633000 1 16.278999 1
Result:
COMPUTED CHARGE ON SYSTEM: +1, THIS IS NOT THE SAME AS THE CHARGE DEFINED IN THE DATA-SET: "CHARGE=-1"
CHARGE SPECIFIED IS INCORRECT. CORRECT THE ERROR BEFORE CONTINUING
Expected behavior
Without MOZYME, the calculation works
JOB ENDED NORMALLY
However it may not be quite correct. Still without MOZYME but adding CHARGES, with the first line being "XYZ PM6-D3H4X EPS=78.5 1SCF CHARGE=-1 THREADS=64 CHARGES", the result is:
Ion Atom No. Type Charge
1 2 N +1
CHARGE SPECIFIED IN DATA SET: -1 IS INCORRECT.
Operating system
MOPAC v23.0.2 from conda-forge, Ubuntu 22.04.4 LTS
Additional context
Happens every time; appars to happen whenever the system contains an ionized sulfonamide, it can be part of a larger molecule.
Reactions are currently unavailable
Metadata
Metadata
Assignees
Labels
No labels