Skip to content

Coordinate output in AUX file has too few significant figures #132

@paulsaxe

Description

@paulsaxe

Describe the bug
The coordinate output in the AUX file has 4 figures after the decimal, which is too few for MOPAC to recognize the symmetry if those coordinates are used for another calculation:

 ATOM_X_OPT:ANGSTROMS[09]=
    1.0823   -0.0542    0.0137
    0.7961   -0.9604    0.1110
    2.0370   -0.0880    0.0174

To Reproduce

PM7 PRECISE GRADIENTS AUX(MOS=10,XP,XS) CHARGE=0 SINGLET
O
optimized with GAFF
O    1.08260292 1  -0.05465095 1   0.01378518 1
H    0.74927322 1  -0.99207258 1   0.11444302 1
H    2.08260292 1  -0.05465095 1   0.01378518 1

or any optimization calculation shows this issue.
Expected behavior
It is not a problem (I think) that the steps along the optimization have fewer figures to keep the file small, but the final geometry of the optimization and any other place where MOPAC changes the geometry should write out more decimal places, probably about 8. The FORCE and THERMO calculations reorient the structure so they create a new geometry.

Metadata

Metadata

Assignees

No one assigned

    Labels

    bugSomething isn't working

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests