Skip to content

[HCL] Salicru SPS 500 ONE supported by nutdrv_qx #3079

@alejsanc

Description

@alejsanc
# upsc salicru

Init SSL without certificate database
battery.charge: 100
battery.voltage: 13.6
battery.voltage.high: 13.00
battery.voltage.low: 10.40
battery.voltage.nominal: 12.0
device.type: ups
driver.debug: 0
driver.flag.allow_killpower: 0
driver.name: nutdrv_qx
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.synchronous: auto
driver.state: quiet
driver.version: 2.8.1
driver.version.data: Voltronic-QS 0.09
driver.version.internal: 0.36
driver.version.usb: libusb-1.0.28 (API: 0x100010a)
input.voltage: 232.9
input.voltage.fault: 232.9
output.current.nominal: 1.0
output.frequency: 50.0
output.frequency.nominal: 50
output.voltage: 232.9
output.voltage.nominal: 230
ups.beeper.status: enabled
ups.delay.shutdown: 30
ups.delay.start: 180
ups.firmware.aux: PM-H
ups.load: 0
ups.productid: 5161
ups.status: OL
ups.type: offline / line interactive
ups.vendorid: 0665
# upscmd -l salicru
Instant commands supported on UPS [salicru]:

beeper.toggle - Toggle the UPS beeper
driver.killpower - Tell the driver daemon to initiate UPS shutdown; should be unlocked with driver.flag.allow_killpower option or variable setting
driver.reload - Reload running driver configuration from the file system (only works for changes in some options)
driver.reload-or-error - Reload running driver configuration from the file system (only works for changes in some options); return an error if something changed and could not be applied live (so the caller can restart it with new options)
driver.reload-or-exit - Reload running driver configuration from the file system (only works for changes in some options); exit the running driver if something changed and could not be applied live (so service management framework can restart it with new options)
load.off - Turn off the load immediately
load.on - Turn on the load immediately
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start.quick - Start a quick battery test

Metadata

Metadata

Assignees

No one assigned

    Labels

    DDLHCLQx protocol driverDriver based on Megatec Q<number> such as new nutdrv_qx, or obsoleted blazer and some othersSalicruSalicru devicesUSBViewPowerSome devices are shipped with ViewPower as their vendor's companion softwareimpacts-release-2.8.1Issues reported against NUT release 2.8.1 (maybe vanilla or with minor packaging tweaks)